repeat">
3 Separation Systems
3 Separation Systems
Goregaon West, Mumbai, Maharashtra
GST No. 27ADHPV4520C1ZO
08048617762 73% Response Rate
Send E-mail

Water Treatment Plant

Our product range includes a wide range of demineralisation plant, water softener plant, waste water treatment plant and membrane biological reactor (mbr).
Request CallBack
Demineralisation Plant
Get Best Quote

Demineralisation Plant

Approx. Price: Rs 50,000 / UnitGet Latest Price
Product Details:
Minimum Order Quantity1 Unit
Water SourceCorporation Supply
Voltage220 Volts/ 380 Volts
BrandPentair/ Thermax/ Purolite/ Leo/ Grundfos
Automation GradeAutomatic
Flow Rate1000 LPH - 25000 LPH
Pre FiltrationCartridge/ Natursl/ Carbon Filtration
Frequency50 Hz
Phase1 Phase/ 3 Phase
Power SourceAC
FeaturesConductivity/ PH/ Level/ Pump Controller
Usage/ApplicationGold/ Rhodium Jewellery/ Electrocoating/ Electroplating/ Chemical Manufacturing
OBR5000 Litres - 500000 Litres
Installation ServiceInstallation/ Commissioning/ AMC
Max Water Recovery Rate90%
Power Consumption1 KW - 5 KW
Number Of Filtration Passes2
Weight200 - 1000 Kilograms
Post FiltrationMixed Bed Polisher/ Cartridge Filtration
Control PanelMCB/ ROTARY SWITCH BASE
Applicable IndustryChemical/ Electroplating
ColorBlue
Treatment TechniqueIon Wxchange
Treated Water Quality1 PPM/ MicroSiemens
Maximum Working Pressure10 Bar
Particle DensityLess 5 Micron
Total Exchange Capacity1.9 Meq
Output TdsLess 1 PPM
Permeate Output100%
Power Supply220 Volts - 380 Volts
Input TdsLess Than 300 PPM
Chemical Besd PlantsHydrochloric Acid/ Caustic Flakes
Inlet Tss Mg LLess Than 50 Mg
Power Kw1 Kw
Working Temp Deg CelsiusMax. 40 Degree Celsius
Capacity Inlet Flow Rate1000 - 25000 LPH
I Deal InNew Only
50060inch

Owing to modern technology of manufacturing process, we offer a wide spectrum of demineralisation plant which is highly appreciated for its effective performance.The plant clean the polluted and infected water by killing the injurious microorganisms and bacteria.We offer sand filters which are available in manual as well as automatic configurations.


Yes! I am interested
Request CallBack
Water Softener Plant
Get Best Quote

Water Softener Plant

Approx. Price: Rs 20,000 / UnitGet Latest Price
Product Details:
Minimum Order Quantity1 Unit
Usage/ApplicationIndustrial
Automation GradeSemi-Automatic
Water SourceRiver Water
ColorNatural
Inlet Flow Rate1000 LPH
Capacity1000 - 50000 LPH

Water softener is a device or a substance, that remove or renders inactive and isolate minerals . This chemical softener is made using premium quality of raw materials and is widely demanded in the global markets. They can also be designed as per the required technical specifications and are easy to install. 


Yes! I am interested
Request CallBack
  • Waste Water Treatment Plant
  • Waste Water Treatment Plant
Waste Water Treatment Plant
Ask For Price

Waste Water Treatment Plant

Product Price : Get Latest Price
Product Details:
Minimum Order Quantity01 Piece
Installation TypeContainerized Plug & Play
Capacity (KLD)10 KLD
Application IndustryPharmaceutical & Chemicals
Inlet Flow Rate(m3/day or m3/hr)10 m3/day
Air Blower Count2 Blowers
Air Blower Power0.5 KW
Treatment TechnologyMixed Bed Bio Reactor(MBBR)
Material Of ConstructionMild Steel
Control ModuleAvailable
Automation GradeSemi-Automatic
Treatment StagesSecondary Treatment
Country of OriginMade in India
Our Waste water Treatment Plants are efficient to provide assessment of various effluent treatment plant and water management systems installed in the industries. These are maintained on the operation and maintenance of ETPs and CETPs, we also upgrade these services after proper Evaluation and selection.

Wastewater treatment plants serve as a critical component of modern society, protecting the public from pollutants which may be present in sewage and effluent from industrial operations. The most widely used method of wastewater treatment is biological treatment using bacteria to break down organic wastes. Properly treated wastewater is returned to the environment for reuse.

 

wastewater treatment plant generally consists of primary, secondary, and sometimes even tertiary treatment. For example, in most municipal sewage treatment plants the primary treatment consists of sedimentation tanks; the secondary treatment means microbiological decomposition or bio-decomposition. Further stages may include micro filtration, ultra filtration or nano filtration for removal of micro-organic particles or ion exchange for hardness or heavy metal ions or activated carbon for organic molecules.

 

 

In the wastewater treatment plant, water is treated in several stages. The first stage takes place at the settling tank, where water circulates to allow particles to settle out of it. The second stage takes place at an aeration tank, where oxygen levels are moderated and living organisms dine on the sewage. The final stage takes place in a clarifier, where remaining solid waste sinks to bottom and can be taken away. How effective is this process? It has been used for over 2,000 years, so we guess pretty effective!


Yes! I am interested
Save time! Get the Best Deal

*Your information is safe with us.

Request CallBack
Membrane Biological Reactor (MBR)
Get Best Quote

Membrane Biological Reactor (MBR)

Approx. Price: Rs 50,000 / onwardsGet Latest Price
  • It consist of biological reactor (bio reactor) with Suspended Biomass and Solids separated by Micro filtration membranes with nominal pore sizes ranging from 0.1 to 0.4 µm,are finding many applications in Waste water treatment.
  • This may be used with aerobic or anaerobic suspended growth bioreactors to separate treated wastewater from the active biomass.
  • The concept of the MBR system consists of utilizing a bioreactor and micro filtration as one unit process for waste water treatment thereby replacing, and in some cases supplementing, the solids separation function of the secondary clarification and effluent filtration.
The ability to eliminate secondary clarification and operate at higher MLSS concentrations provides the following advantages:
  • Higher volumetric loading rates and thus shorter reactor hydraulic retention times.
  • Longer SRTs resulting in less sludge production.
  • Operation at low dissolved oxygen concentrations with potential for simultaneous nitrification – denitrification in the long SRT designs.
  • High – Quality effluent in terms of low turbidity, bacteria, TSS, and BOD.
  • Less space required for the waste water treatment.

Yes! I am interested

Explore more products

X